The main technical parameters


1. Operating pressure: 0.05Mpa-0.5Mpa

2. Recommended pressure: 0.1Mpa-0.5Mpa

3. Cold water supply temperature: 5 ℃ -29 ℃

4. Hot water supply temperature: 55 ℃ -85 ℃

5. Water temperature range: 20 ℃ -50 ℃

6. Set the security button: 38 ℃

7. Safety parameters: loss of cold water, the first 5 seconds the amount of water is automatically reduced to 1.9L / Min, outflow <150Ml outflow temperature <49 ℃


The main technical indicators

1. Working pressure: 0.1MPa ~ 0.5MPa; water pressure: ≥ 1.05MPa;

2. Hot and cold water pressure difference: ≤ 20%;

3. Water temperature: hot water 32 ℃ ~ 80 ℃; cold water 4 ℃ ~ 29 ℃;

4. Temperature adjustment range: 32 ℃ ~ 42 ℃ (resolution 1 ℃, according to the requirements of the appropriate adjustment range, over-temperature temperature up to 48 ± 2 ℃); temperature control accuracy: ± 2 ℃;

5. Temperature control speed: ≤ (2s / ℃ +5 s);

6. Delay off the water time: 60s

7. Degree of protection: control panel / IP68; control box / IP54;

8. The maximum working power: ≤ 12W.